Product:
Fan
Centrifugal Fan
Constructions:
Blower Eurovent : TFF Series
CENTRIFUGAL MEDIUM AND HIGH-PRESSURE FAN. DIRECTLY COUPLED MOTOR.Drive | : | Direct Drive |
Pressure | : | Hight |
Impeller | : | Forward Curve |
St. Pressure | : | 430 - 1760 mmH2O |
Impeller Dia | : | 500 - 900 mm. |
Air flow | : | 10 - 140 cmm. |
Spark proof construction:
when explosive fluids are carried or when the plant is installed in dangerous environments, the parts that come into contact with the intaken fluid are constructed by material without iron content to avoid rubbing, motor on request is supplied in special construction.
Corosionproofing construction:
when corrosive fluids are carried, the parts that come into contact with the fluid are painted with special paints or they are constructed with special materials as austentic stainless steels (AISI 304-316 etc.). Constructions can be effected according to the customer’s particular needs.
Usage:
● Also for the suction of very dusty air.
● The fans of this series are particularly suitable for pneumatic conveyances, in cement factories, in the air feeding of the cupolas, in foundries and in oil burners, in mills, in “pasta” factories, in chemical, metallurgical and iron industries where small capacities with medium and high pressures are required.
● The temperature of the fluid sucked in must not exceed 80°C without cooling fan and 150°C with cooling fan.
● The fan is revolvable.
Uses of Variable Speed Drives please pay attention to the possible overheating of the motor due to a lower rpm/Hz than recommended by the motor supplier.
● The fans of this series are particularly suitable for pneumatic conveyances, in cement factories, in the air feeding of the cupolas, in foundries and in oil burners, in mills, in “pasta” factories, in chemical, metallurgical and iron industries where small capacities with medium and high pressures are required.
● The temperature of the fluid sucked in must not exceed 80°C without cooling fan and 150°C with cooling fan.
Blower Eurovent : TFF Series
Item | Model | HP | Poles | Air Volume | Pressure | Inlet (D)
mm.
|
Outlet (axb)
mm.
|
|
cmm | cfm | mmWg | ||||||
1 | FanBlower TFF 502/A | 3 | 2 | 10 - 18 | 353 - 636 | 485 - 470 | 165 | 125x90 |
2 | FanBlower TFF 502/B | 4 | 2 | 10 - 25 | 353 - 883 | 485 - 430 | 165 | 125x90 |
3 | FanBlower TFF 561/A | 5.5 | 2 | 12 - 25 | 424 - 883 | 655 - 640 | 185 | 140x100 |
4 | FanBlower TFF 561/B | 7.5 | 2 | 12 - 35 | 424 - 1,237 | 655 - 570 | 185 | 140x100 |
5 | FanBlower TFF 632/A | 7.5 | 2 | 14 - 28 | 495 - 989 | 735 - 720 | 205 | 160x112 |
6 | FanBlower TFF 632/B | 10 | 2 | 14 - 45 | 495 - 1,590 | 735 - 650 | 205 | 160x112 |
7 | FanBlower TFF 631/A | 10 | 2 | 16 - 35 | 565 - 1,237 | 835 - 800 | 205 | 160x112 |
8 | FanBlower TFF 712/A | 10 | 2 | 18 - 28 | 636 - 989 | 935 - 915 | 229 | 180x125 |
9 | FanBlower TFF 712/C | 15 | 2 | 18 - 45 | 636 - 1,590 | 935 - 905 | 229 | 180x125 |
10 | FanBlower TFF 712/D | 20 | 2 | 18 - 63 | 636 - 2,226 | 935 - 800 | 229 | 180x125 |
11 | FanBlower TFF 711/A | 15 | 2 | 22 - 40 | 777 - 1,413 | 1,080 - 1,060 | 229 | 180x125 |
12 | FanBlower TFF 711/B | 20 | 2 | 22 - 56 | 777 - 1,978 | 1,080 - 1,030 | 229 | 180x125 |
13 | FanBlower TFF 711/C | 25 | 2 | 22 - 71 | 777 - 2,508 | 1,080 - 925 | 229 | 180x125 |
14 | FanBlower TFF 802/A | 20 | 2 | 28 - 45 | 989 - 1,590 | 1,225 - 1,180 | 255 | 200x140 |
15 | FanBlower TFF 802/B | 25 | 2 | 28 - 63 | 989 - 2,226 | 1,225 - 1,160 | 255 | 200x140 |
16 | FanBlower TFF 802/C | 30 | 2 | 28 - 80 | 989 - 2,826 | 1,225 - 1,120 | 255 | 200x140 |
17 | FanBlower TFF 801/A | 20 | 2 | 31 - 40 | 1,095 - 1,413 | 1,360 - 1,330 | 255 | 200x140 |
18 | FanBlower TFF 801/B | 25 | 2 | 31 - 50 | 1,095 - 1,767 | 1,390 - 1,330 | 255 | 200x140 |
19 | FanBlower TFF 801/C | 30 | 2 | 31 - 63 | 1,095 - 2,226 | 1,390 - 1,330 | 255 | 200x140 |
20 | FanBlower TFF 801/D | 40 | 2 | 31 - 90 | 1,095 - 3,180 | 1,390 - 1,270 | 255 | 200x140 |
21 | FanBlower TFF 902/A | 30 | 2 | 35 - 50 | 1,237 - 1,767 | 1,540 - 1,490 | 286 | 224x160 |
22 | FanBlower TFF 902/B | 40 | 2 | 35 - 71 | 1,237 - 2,508 | 1,550 - 1,490 | 286 | 224x160 |
23 | FanBlower TFF 902/C | 50 | 2 | 35 - 100 | 1,237 - 3,533 | 1,550 - 1,490 | 286 | 224x160 |
24 | FanBlower TFF 902/D | 60 | 2 | 35 - 125 | 1,237 - 4,416 | 1,550 - 1,410 | 286 | 224x160 |
25 | FanBlower TFF 901/A | 40 | 2 | 40 - 56 | 1,413 - 1,978 | 1,750 - 1,690 | 286 | 224x160 |
26 | FanBlower TFF 901/B | 50 | 2 | 40 - 80 | 1,413 - 2,826 | 1,760 - 1,690 | 286 | 224x160 |
27 | FanBlower TFF 901/C | 60 | 2 | 40 - 100 | 1,413 - 3,533 | 1,760 - 1,690 | 286 | 224x160 |
28 | FanBlower TFF 901/D | 75 | 2 | 40 - 140 | 1,413 - 4,946 | 1,760 - 1,570 | 286 | 224x160 |
● The fan is revolvable.
Uses of Variable Speed Drives please pay attention to the possible overheating of the motor due to a lower rpm/Hz than recommended by the motor supplier.
ติดตาม Eurovent Blower
Eurovent Blower มี LINE OFFICIAL ACCOUNT แล้วนะ
ติดตามเรื่องราวดีๆแบบอินเทรนด์ ได้ทุกวันผ่าน LINE ID @euroventblower
Product Spec
Drive:
Direct
Pressure:
High
Impeller: