TRG (Backward Curve Direct Drive)

Product: 
Fan
Centrifugal Fan
Constructions: 

Blower Eurovent :TRG Series

CENTRIFUGAL HIGH-PRESSURE FAN. HIGH EFFICIENCY REVERSE-BLADE IMPELLER. DIRECTLY COUPLED MOTOR.
 
Drive : Direct Drive
Pressure : Hight
Impeller : Backward Curve
St. Pressure : 260 - 2800 mmH2O
Impeller Dia : 500 - 1120 mm.
Air flow : 20 - 560 cmm.

Spark proof construction :
when explosive fluids are carried or when the plant is installed in dangerous environments, the parts that come into contact with the intaken fluid are constructed by material without iron content to avoid rubbing, motor on request is supplied in special construction.

Corosionproofing construction :
when corrosive fluids are carried, the parts that come into contact with the fluid are painted with special paints or they are constructed with special materials as austentic stainless steels (AISI 304-316 etc.). Constructions can be effected according to the customer’s particular needs.
 
Usage: 
● For the suction of clean and dusty air. These types of high pressure fans are characterized by a high output with saving of electric power as they have a special fan wheel with reversed blades (Negative) assembled.
● These types of fans are particularly suitable for pneumatic conveyances, in cement factories, in the air feeding fo the cupolas in foundries and in oil burners, in the mills, in “pasta” factories, in chemical, metallurgical and iron industries where small capacities with medium and high pressures are required.
● For temperatures of the transported fluid higher than 90°C up to 350°C a small heat stopping fan is splined to the shaft between support and scroll; besides the fan is painted with a special aluminium paint suitable for high temperatures.

Blower Eurovent : TRG Series

Item Model HP Poles Air Volume Pressure Inlet (D)
mm.
Outlet (axb)
mm.
cmm cfm mmWg
1 FanBlower TRG 501/A 4 2 20 - 28 707 - 989 520 - 530 205 180x125
2 FanBlower TRG 501/B 5.5 2 20 - 45 707 - 1,590 410 - 530 205 180x125
3 FanBlower TRG 562/A 7.5 2 28 - 56 989 - 1,978 490 - 600 229 200x140
4 FanBlower TRG 561/A 7.5 2 28 - 40 989 - 1,413 655 - 670 229 200x140
5 FanBlower TRG 561/B 10 2 28 - 71 989 - 2,508 460 - 670 229 200x140
6 FanBlower TRG 632/A 10 2 35 - 45 1,237 - 1,590 790 - 800 255 224x160
7 FanBlower TRG 632/C 15 2 35 - 90 1,237 - 3,180 585 - 800 255 224x160
8 FanBlower TRG 631/B 15 2 40 - 71 1,413 - 2,508 780 - 850 255 224x160
9 FanBlower TRG 712/A 20 2 50 - 80 1,767 - 2,826 940 - 980 286 250x180
10 FanBlower TRG 712/B 25 2 50 - 112 1,767 - 3,957 825 - 980 286 250x180
11 FanBlower TRG 711/A 25 2 56 - 90 1,978 - 3,180 1,030 - 1,070 286 250x180
12 FanBlower TRG 711/B 30 2 56 - 125 1,978 - 4,416 875 - 1,070 286 250x180
13 FanBlower TRG 802/A 30 2 71 - 90 2,508 - 3,180 1,230 - 1,240 321 280x200
14 FanBlower TRG 802/B 40 2 71 - 125 2,508 - 4,416 1,140 - 1,240 321 280x200
15 FanBlower TRG 802/C 50 2 71 - 180 2,508 - 6,359 960 - 1,240 321 280x200
16 FanBlower TRG 801/A 40 2 80 - 112 2,826 - 3,957 1,320 - 1,390 321 280x200
17 FanBlower TRG 801/B 50 2 80 - 160 2,826 - 5,653 1,170 - 1,390 321 280x200
18 FanBlower TRG 801/C 60 2 80 - 200 2,826 - 7,066 1,020 - 1,390 321 280x200
19 FanBlower TRG 801/D 7.5 4 35 - 90 1,237 - 3,180 260 - 325 321 280x200
20 FanBlower TRG 902/A 60 2 100 - 140 3,533 - 4,946 1,570 - 1,610 361 315x224
21 FanBlower TRG 902/B 75 2 100 - 200 3,533 - 7,066 1,430 - 1,610 361 315x224
22 FanBlower TRG 902/C 100 2 100 - 280 3,533 - 9,892 1,110 - 1,610 361 315x224
23 FanBlower TRG 902/D 10 4 45 - 112 1,590 - 3,957 305 - 370 361 315x224
24 FanBlower TRG 901/A 75 2 112 - 160 3,957 - 5,653 1,720 - 1,750 361 315x224
25 FanBlower TRG 901/B 100 2 112 - 250 3,957 - 8,833 1,450 - 1,750 361 315x224
26 FanBlower TRG 901/C 10 4 50 - 100 1,767 - 3,533 360 - 410 361 315x224
27 FanBlower TRG 1002/A 125 2 140 - 225 4,946 - 7,949 2,040 - 2,100 406 355x250
28 FanBlower TRG 1002/B 150 2 140 - 280 4,946 - 9,892 1,900 - 2,100 406 355x250
29 FanBlower TRG 1002/C 175 2 140 - 355 4,946 - 12,542 1,600 - 2,100 406 355x250
30 FanBlower TRG 1002/D 15 4 56 - 140 1,978 - 4,946 390 - 475 406 355x250
31 FanBlower TRG 1001/A 150 2 160 - 250 5,653 - 8,833 2,100 - 2,210 406 355x250
32 FanBlower TRG 1001/B 175 2 160 - 315 5,653 - 11,129 1,900 - 2,210 406 355x250
33 FanBlower TRG 1001/C 220 2 160 - 450 5,653 - 15,899 1,430 - 2,210 406 355x250
34 FanBlower TRG 1001/D 20 4 63 - 160 2,226 - 5,653 430 - 520 406 355x250
35 FanBlower TRG 1122/A 220 2 200 - 315 7,066 - 11,129 2,450 - 2,550 506 400x280
36 FanBlower TRG 1122/B 270 2 200 - 450 7,066 - 15,899 2,200 - 2,550 506 400x280
37 FanBlower TRG 1122/C 340 2 200 - 560 7,066 - 19,785 1,800 - 2,550 506 400x280
38 FanBlower TRG 1122/D 30 4 80 - 200 2,826 - 7,066 515 - 605 506 400x280
39 FanBlower TRG 1121/A 270 2 225 - 400 7,949 - 14,132 2,550 - 2,800 506 400x280
40 FanBlower TRG 1121/B 340 2 225 - 500 7,949 - 17,665 2,300 - 2,800 506 400x280
41 FanBlower TRG 1121/C 40 4 90 - 250 3,180 - 8,833 535 - 675 506 400x280

● The fan is not revolvable.
Uses of Variable Speed Drives please pay attention to the possible overheating of the motor due to a lower rpm/Hz than recommended by the motor supplier.


ติดตาม Eurovent Blower




Eurovent Blower มี LINE OFFICIAL ACCOUNT แล้วนะ
ติดตามเรื่องราวดีๆแบบอินเทรนด์ ได้ทุกวันผ่าน
 LINE ID @euroventblower
เพิ่มเพื่อน

Product Spec

Drive: 
Direct
Pressure: 
High
Impeller: 
Backward